Tier 1. Class A. The Best Data Centers.
Live Chat
30 Day Guarantee
All Triple8 services are backed with a full 30 Day Money-Back guarantee.
Data Center
Triple8 Network's primary datacenter is located in the One Wilshire building in downtown Los Angeles. An icon in the Los Angeles skyline for more than two decades, One Wilshire is considered to be the single most important point of connectivity in the Western United States, if not the world. With over 260 service providers located onsight, One Wilshire is one of the world's most interconnected facilities.

Data Center Infrastructure
  • Home to almost every major carrier in the World, including Level3, Global Crossing, UUnet, Mzima, Qwest, MCI, Savvis, Cogent, and XO.
  • Fire Protection - The One Wilshire Building is protected by a state-of-the-art fire life safety system and Triple8's suites are installed with pre-action fire sprinkler systems throughout all the collocation areas.
  • Liebert HVAC units within the facility are served from the buildings central plant consisting of three 1,000 ton and two 500 ton centrifugal chillers, each with two pumps for redundancy.
  • Power - One Wilshire is equipped with four (4), 3750 KVA, 480 volt transformers and one (1) 5,000 KVA, 4160 transformer all fed by the Department of Water and Power. Triple8 OneWilshire, in turn, is connected to the building’s buss duct risers, which provide up to 690 amps at 480 volts of commercial power to Triple8's facilities. In addition, Triple8 OneWilshire maintains two DC power plants with up to 800 amp of DC capacity. Individual AC and DC outlets are available to customers.
  • Emergency Power - All of Triple8's transformers for commercial power service are connected with Automatic Transfer Switches to a building emergency generator. One Wilshire currently maintains five 2,000kw generators, which support the tenants' main electrical power in the event of a power interruption. The back-up generator power is distributed to the tenants via multiple 480v, 3 phase, 4 wire bus ducts.
  • Currently there are five 2.2 MW emergency generators supplied by enough diesel fuel to run for 30 days. Only three generators are required to full operate the building. These generators alone could power a city of 20,000 people.
  • UPS Systems - Provided by 5 - 560KVA Emerson UPS systems with 12 hours of battery back up.
Security Features
  • Card access control at all interior and exterior doors
  • 24/7/365 on-site security staff and 30 days of stored CCTV Surveillance video
  • Entry to the underground floors an only occur through secure gates
  • Onsite Security personnel require all personal to display their pass before entry
  • Visitors have to be signed in and escorted by authorized personnel to our data center.
  • Triple8 data center has additional security personnel onsite 24/7